021-MVP-R Rev A MVP-R User Manual 10
Copyright © High Country Tek, Inc. 2013
MVP-R Ramping Controller
Parameter List
The following table outlines the MVP-R parameters as well as the limits and units of measure for each parameter.
Parameter
Limits
Units
MVP-RPx-xxx
Version #
Ramp time factor
X1, /10
Mode #
Ramp up time
0.0 to 120.0
Seconds
Ramp down time
*
0.0 to 120.0
Seconds
Minimum output
0 to 600
**
mA
Maximum output
0 to 600
**
mA
Dither frequency
80 to 300,
(select OFF for 1000Hz)
Hz.
Output current
mA
Supply voltage
Volts
Fault status
Fault
*
RP2 only
**
0 to 1.2A for 12A version, 0 to 2.5A for 25A version