P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 49
Using the input fields on the right side of the
window shown you can reverse the LED’s
display side and set the Power On period for the
DVC7.
3.16 Program Variables
Program variables are identifiers that are used
by your application program to refer to specific input values and to control the operation of a specific output.
This section is divided into various subsections according to Input/Output category. The following gives the
definition of all the program variables:
LED STATE MEANING
Off No PWMs are active.
RED >> GREEN The greatest PWM % 0 -> 100%
Flashing GREEN PWM or High Side output Open circuit detected
Flashing RED PWM or High Side output Short circuit detected
LED3: Error / System Enable / Module Ready
LED STATE MEANING
On RED Unrecoverable error
On Yellow System Enable active (Power cycle required to reset)
On GREEN Module Ready
Flashing RED Low voltage (<8.5vdc) into DVC7
LED4: Error Code
LED STATE MEANING
Off No errors
On RED PWM1 Open or Short detected
On GREEN PWM2 Open or Short detected
Flashing Yellow High Side Open or Short detected
Flashing RED Application defined blink codes when blinkcode
variable > 0.